Indoor air quality and thermal comfort in temporary houses occupied after the Great East Japan Earthquake.

AbstractUNLABELLED:
Thermal conditions and indoor concentrations of aldehydes, volatile organic compounds (VOCs), and NO2 were investigated in 19 occupied temporary houses in 15 temporary housing estates constructed in Minamisoma City, Fukushima, Japan. The data were collected in winter, spring, and summer in January to July 2012. Thermal conditions in temporary log houses in the summer were more comfortable than those in pre-fabricated houses. In the winter, the indoor temperature was uncomfortably low in all of the houses, particularly the temporary log houses. Indoor air concentrations for most aldehydes and VOCs were much lower than the indoor guidelines, except for those of p-dichlorobenzene, acetaldehyde, and total VOCs. The indoor p-dichlorobenzene concentrations exceeded the guideline (240 μg/m(3)) in 18% of the temporary houses, and the 10(-3) cancer risk level (91 μg/m(3)) was exceeded in winter in 21% due to use of moth repellents by the occupants. Indoor acetaldehyde concentrations exceeded the guideline (48 μg/m(3) ) in about half of the temporary houses, likely originating from the wooden building materials. Indoor NO2 concentrations in the temporary houses were significantly higher in houses where combustion heating appliances were used (0.17 ± 0.11 ppm) than in those where they were not used (0.0094 ± 0.0065 ppm).
PRACTICAL IMPLICATIONS:
In the winter, log-house-type temporary houses are comfortable in terms of humidity, dew condensation, and fungi based on the results of questionnaires and measurements, whereas pre-fabricated temporary houses are more comfortable in terms of temperature. In the summer, log-house-type temporary houses are comfortable in terms of temperature and humidity. More comfortable temporary housing in terms of temperature and humidity year-round is needed. Indoor air concentrations of p-dichlorobenzene and NO2 were quite high in some temporary houses due to occupants’ activities, such as use of moth repellents and combustion heating appliances. The government should provide recommendations for safe use of temporary houses by occupants.
AuthorsN Shinohara, M Tokumura, M Kazama, Y Yonemoto, M Yoshioka, N Kagi, K Hasegawa, H Yoshino, U Yanagi
JournalIndoor air (Indoor Air) Vol. 24 Issue 4 Pg. 425-37 (Aug 2014) ISSN: 1600-0668 [Electronic] England
PMID24354902 (Publication Type: Journal Article)
Copyright© 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Chemical References
  • Air Pollutants
  • Volatile Organic Compounds
  • Nitrogen Dioxide
Topics
  • Air Pollutants (analysis)
  • Air Pollution, Indoor (analysis)
  • Chi-Square Distribution
  • Earthquakes
  • Environmental Exposure (analysis)
  • Environmental Monitoring (methods)
  • Heating
  • Housing
  • Humans
  • Humidity
  • Japan
  • Nitrogen Dioxide (analysis)
  • Seasons
  • Surveys and Questionnaires
  • Temperature
  • Volatile Organic Compounds (analysis)