HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Comparative morphometry of the antebrachial and crural interosseous membranes: preliminary study for the use of the crural interosseous membrane in the surgical repair of the antebrachial interosseous membrane tears.

AbstractINTRODUCTION:
Traumatic tears of the antebrachial interosseous membrane (AIOM) on its whole length are difficult to treat, particularly in the Essex-Lopresti syndrome. The number of ligamentoplasty techniques described in the literature witnesses the difficulty of its reconstruction and the absence of reliable and satisfying procedure. The aim of this study was to explore a new way of treatment, which consists in replacing the AIOM by the crural interosseous membrane (CIOM), harvested from the same patient.
MATERIALS AND METHODS:
A morphometric study of the AIOM and CIOM has been conducted on both sides of 15 formalin preserved corpses (i.e. 30 AIOM and 30 CIOM). Studied data were: length of forearms and legs, length and width (at different locations) of the membranes, in situ and after harvesting, and orientation of their fibers. The thickness of membrane was also measured but only after harvesting.
RESULTS:
Concerning the AIOM, the mean length was 13.3 cm in situ and 12.8 cm after harvesting. Its width was maximal at the union of middle and distal thirds with an average value of 1.7 cm in situ and 1.45 cm after harvesting. Mean thickness was 1 mm. Anterior fibers were oblique distally and medially (20.5° ± 0.95°), and posterior fibers were oblique distally and laterally (40° ± 3.4°). Concerning the CIOM, the mean length was 24.75 cm in situ and 23.9 cm after harvesting. Its width was maximal at the union of proximal and middle thirds with an average value of 2.3 cm in situ and 1.85 cm after harvesting. Mean thickness was 0.5 mm. Obliquity of its fibers was reverse of that of the AIOM: the anterior fibers were quite oblique distally and laterally (13° ± 2.6°), and the posterior fibers oblique were oblique distally and medially (24.2° ± 2.48°).
DISCUSSION:
From these results, one may conclude that the largest length and width of the CIOM allow its use as substitute for the injured AIOM. The orientation of its fibers should necessitate either its reversal while using the same side or the use of the CIOM of the opposite side; its relative sharpness could signify that its biomechanical properties could be worse. A biomechanical study is necessary to evaluate how this new way of replacing the AIOM could resist to the strains imposed on the forearm.
AuthorsDriss Elamrani, Aurélien Aumar, Guillaume Wavreille, Christian Fontaine
JournalSurgical and radiologic anatomy : SRA (Surg Radiol Anat) Vol. 36 Issue 4 Pg. 333-9 (May 2014) ISSN: 1279-8517 [Electronic] Germany
PMID24036679 (Publication Type: Journal Article)
Topics
  • Aged
  • Aged, 80 and over
  • Cadaver
  • Female
  • Forearm (anatomy & histology)
  • Forearm Injuries (surgery)
  • Humans
  • Leg (anatomy & histology)
  • Ligaments (anatomy & histology, injuries, surgery)
  • Male
  • Membranes (anatomy & histology, injuries, transplantation)
  • Middle Aged

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: