HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Treatment of visual problems after intracorneal ring implantation.

AbstractPURPOSE:
To report the effect of wavefront-guided photorefractive keratectomy and corneal collagen cross-linking (CXL) on visual problems after Ferrara ring segment placement.
MATERIALS AND METHODS:
A 32-year-old male patient was treated with a Ferrara ring segment for keratoconus. One year later, the ring was removed due to severe glare complaints. After 6 months, wavefront-guided photorefractive keratectomy and CXL were applied simultaneously to correct high order aberration and refractive error.
RESULTS:
Six months after the wavefront-guided photorefractive keratectomy and CXL, the uncorrected distance visual acuity was 20/25, and there was a 30% decrease in coma aberrations. The glare complaint regressed.
CONCLUSION:
Wavefront-guided surface ablation and CXL may reduce high order aberrations and glare complaints after intrastromal corneal ring implantation.
AuthorsAydin Yildirim, Hasim Uslu, Necip Kara, Engin Bilge Ozgurhan
JournalClinical ophthalmology (Auckland, N.Z.) (Clin Ophthalmol) Vol. 7 Pg. 1251-5 ( 2013) ISSN: 1177-5467 [Print] New Zealand
PMID23836954 (Publication Type: Case Reports)