HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

The impact of neutral-pH peritoneal dialysates with reduced glucose degradation products on clinical outcomes in peritoneal dialysis patients.

Abstract
Neutral-pH peritoneal dialysates, with reduced glucose degradation products (GDPs), have been developed to reduce peritoneal membrane damage. Here our review evaluated the impact of these solutions on clinical outcomes using data from The Cochrane CENTRAL Registry, MEDLINE, Embase, and reference lists for randomized trials of biocompatible solutions. Summary estimates of effect were obtained using a random-effects model of 20 eligible trials encompassing 1383 patients. The quality of studies was generally poor, such that 13 studies had greater than a 20% loss to follow-up and only 3 trials reported adequate concealment of allocation. Use of neutral-pH dialysates with reduced GDPs resulted in larger urine volumes (7 trials; 520 patients; mean difference 126 ml/day, 95% CI 27-226), improved residual renal function after 12 months (6 trials; 360 patients; standardized mean difference 0.31, 95% confidence interval 0.10-0.52), and a trend to reduced inflow pain (1 trial; 58 patients; relative risk 0.51, 95% CI 0.24-1.08). However, there was no significant effect on body weight, hospitalization, peritoneal solute transport rate, peritoneal small-solute clearance, peritonitis, technique failure, patient survival, or adverse events. No significant harms were identified. Thus, based on generally poor quality trials, the use of neutral-pH peritoneal dialysates with reduced GDPs resulted in greater urine volumes and residual renal function after 12 months, but without other clinical benefits. Larger, better-quality studies are needed for accurate evaluation of the impact of these newer dialysates on patient-level hard outcomes.
AuthorsYeoungjee Cho, David W Johnson, Sunil V Badve, Jonathan C Craig, Giovanni F M Strippoli, Kathryn J Wiggins
JournalKidney international (Kidney Int) Vol. 84 Issue 5 Pg. 969-79 (Nov 2013) ISSN: 1523-1755 [Electronic] United States
PMID23698236 (Publication Type: Journal Article, Meta-Analysis, Research Support, Non-U.S. Gov't, Review)
Chemical References
  • Dialysis Solutions
  • Glucose
Topics
  • Dialysis Solutions (adverse effects, chemistry, metabolism, therapeutic use)
  • Glucose (metabolism)
  • Humans
  • Hydrogen-Ion Concentration
  • Kidney (metabolism, physiopathology)
  • Kidney Diseases (metabolism, physiopathology, therapy)
  • Peritoneal Dialysis (adverse effects, methods)
  • Randomized Controlled Trials as Topic
  • Treatment Outcome

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: