AbstractAIMS:
We investigated whether sirolimus-eluting stents (SES) are superior to next-generation zotarolimus-eluting stents (ZES) in treating patients with total coronary occlusions (TCO).
METHODS AND RESULTS:
In a prospective, randomised trial we compared the SES with the zotarolimus-eluting stent (ZES; Endeavor or Resolute) after successful recanalisation of TCO. During the first phase of the trial, 51 patients were assigned to receive the SES and 46 patients to receive the Endeavor ZES. In the second phase we randomised 103 patients to the SES group and 104 patients to the Resolute ZES group. The primary endpoint was in-segment late lumen loss at eight-month follow-up. At eight months, patients in the SES group had less in-segment and in-stent late loss as compared to the Endeavor group: -0.13±0.3 mm vs. 0.27±0.6 mm (p=0.0002) and -0.13±0.5 mm vs. 0.54±0.5 mm (p<0.0001), respectively. In contrast, the SES and the Resolute ZES showed comparable amounts of in-segment (-0.03±0.7 mm vs. -0.10±0.7 mm, p=0.6) and in-stent (0.03±0.8 mm vs. 0.05±0.8 mm, p=0.9) late loss.
CONCLUSIONS:
In the treatment of TCOs, the SES was associated with superior angiographic outcomes compared to the Endeavor ZES. On the other hand, the SES and the Resolute ZES showed comparable angiographic outcomes.
AuthorsBen J L Van den Branden, Koen Teeuwen, Jacques J Koolen, René J van der Schaaf, José P S Henriques, Jan G P Tijssen, Johannes C Kelder, Paul H M J Vermeersch, Benno J W M Rensing, Maarten J Suttorp
JournalEuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology (EuroIntervention) Vol. 9 Issue 7 Pg. 841-53 (Nov 2013) ISSN: 1969-6213 [Electronic] France
PMID23628457 (Publication Type: Journal Article, Research Support, Non-U.S. Gov't)
Chemical References
  • Sirolimus
Topics
  • Coronary Angiography
  • Coronary Occlusion
  • Coronary Restenosis
  • Coronary Vessels
  • Drug-Eluting Stents
  • Humans
  • Prospective Studies
  • Sirolimus
  • Treatment Outcome

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: