Comparison of 10 hemostatic dressings in a groin puncture model in swine.

AbstractBACKGROUND:
The use of mineral (clay) or biologic (chitosan) materials has improved the efficacy of dressings used in the bleeding control of noncompressible areas. A series of novel manufactured products already evaluated in a vascular transection model was further compared in a severe vascular puncture injury model.
METHODS:
Ten hemostatic dressings were tested in anesthetized Yorkshire swine hemorrhaged for 45 seconds in a femoral arterial puncture model. Application of these dressings was followed by 5 minutes of compression (about 175 mm Hg), and at 15 minutes, 500 mL resuscitation fluid (Hextand) was infused during a 30-minute period. The animals were monitored for a 3-hour experimental observation period. Primary outcomes were incidence of bleeding after dressing application and animal survival.
RESULTS:
Blood loss was 18.8% +/- 5.2% estimated blood volume (EBV) after 45 seconds of free bleeding. Relative performance of dressings is characterized as groups of dressings that performed similarly. Recurrence of bleeding after application was observed with most dressings and was lower with Woundstat, Celox, X-Sponge, and ACS+ (35% +/- 49%) compared with FP-21, Hemcon, Chitoflex, and Bloodstop (79% +/- 43%; P < .01). Blood loss after treatment was 25.3% +/- 18.4% EBV for the top four dressings and 53.0% +/- 18.4% EBV for the bottom four (P < .05). Survival was higher for top four vs bottom four dressings (78% +/- 12% vs 25% +/- 0%, respectively; P < .01). Overall performance of these dressings according to survival, incidence of bleeding, and post-treatment blood loss, yielded similar ranking as with a previously tested transection injury model.
CONCLUSIONS:
The findings indicated that the efficacy of Woundstat, Celox, X-Sponge, and ACS+ were similar and superior in improving survival, hemostasis, and maintenance of mean arterial pressure in an actively bleeding wound caused in this severe vascular injury model.
AuthorsFrançoise Arnaud, Kohsuke Teranishi, Toshiki Tomori, Walter Carr, Richard McCarron
JournalJournal of vascular surgery (J Vasc Surg) Vol. 50 Issue 3 Pg. 632-9, 639.e1 (Sep 2009) ISSN: 1097-6809 [Electronic] United States
PMID19700097 (Publication Type: Comparative Study, Journal Article)
Topics
  • Animals
  • Bandages
  • Blood Pressure
  • Blood Volume
  • Disease Models, Animal
  • Equipment Design
  • Femoral Artery (injuries)
  • Groin (blood supply)
  • Hemorrhage (etiology, prevention & control)
  • Hemostatic Techniques (instrumentation)
  • Materials Testing
  • Punctures
  • Recurrence
  • Severity of Illness Index
  • Swine
  • Time Factors
  • Wounds and Injuries (etiology, therapy)

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: