HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Quantitative assessment of homograft function 1 year after insertion into the pulmonary position: impact of in situ homograft geometry on valve competence.

AbstractAIMS:
To prospectively evaluate homograft function with cardiac magnetic resonance (CMR) imaging 1 year after insertion into the pulmonary position, and to assess the impact of in situ homograft geometry, surgical factors, and 'intrinsic' homograft properties on early valve incompetence.
METHODS AND RESULTS:
A total of 60 patients (mean age 21 +/- 10 years; 35 females) with congenital heart disease underwent pulmonary valve replacement with homograft insertion and were prospectively enrolled into a study protocol that included serial echocardiography and CMR 1 year after surgery. None of the patients had homograft stenosis but 10 (17%) had significant homograft incompetence (i.e. pulmonary regurgitation fraction >20% on CMR). A higher incidence of 'eccentric' pulmonary forward flow pattern (P < 0.001, Fisher's exact test), more acute 'homograft distortion angle' (P < 0.001), larger relative 'annular' size (P < 0.01), and greater pre-homograft right ventricular outflow tract (RVOT) diameters (P = 0.01) at CMR was seen in those with worse homograft function. In a backward multivariate linear regression model, 'eccentric' pulmonary forward flow pattern (r(part) = 0.36, P < 0.001), 'homograft distortion angle' (r(part) = 0.31, P = 0.001), and pre-homograft RVOT diameter (r(part) = 0.19, P = 0.03) were independently associated with the degree of pulmonary regurgitation (in %) at 1 year.
CONCLUSION:
Using CMR, in this prospective cohort study, we have shown that significant valve incompetence is present in one-sixth of patients after homograft insertion into the pulmonary position, and that alterations in the in situ homograft geometry were associated with the likelihood of developing valve incompetence. These findings imply that mechanical factors may have an important impact on homograft performance.
AuthorsJohannes Nordmeyer, Victor Tsang, Régis Gaudin, Philipp Lurz, Alessandra Frigiola, Alexander Jones, Silvia Schievano, Carin van Doorn, Philipp Bonhoeffer, Andrew M Taylor
JournalEuropean heart journal (Eur Heart J) Vol. 30 Issue 17 Pg. 2147-54 (Sep 2009) ISSN: 1522-9645 [Electronic] England
PMID19502232 (Publication Type: Journal Article, Research Support, Non-U.S. Gov't)
Topics
  • Adult
  • Echocardiography
  • Female
  • Graft Survival
  • Heart Defects, Congenital (pathology, physiopathology, surgery)
  • Heart Valve Prosthesis
  • Heart Valve Prosthesis Implantation (methods)
  • Humans
  • Magnetic Resonance Angiography
  • Male
  • Prospective Studies
  • Pulmonary Valve (surgery)
  • Pulmonary Valve Insufficiency (pathology, physiopathology, surgery)
  • Stroke Volume (physiology)
  • Transplantation, Homologous
  • Treatment Outcome
  • Young Adult

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: