Needle revision of filtering blebs.

AbstractThe modern version of trabeculectomy is associated with a very high success rate. As time progresses after surgery, failure of filtration, however, is common, as are problems with filtering blebs such as leaks and dysesthesia. Needle revision of filtering blebs is a useful adjunct to failed, failing, leaking, or dysesthetic trabeculectomy filters and can be performed in a variety of settings and techniques with fairly good results. Although varied techniques have been reported, there is no definitive "best" surgical approach. Needle revision should be considered before more aggressive surgical intervention, and in some cases before additional medical therapy. Owing to the paucity of rigorously conducted clinical studies, this review focuses on clinical experience with bleb needle revision.
AuthorsRobert M Feldman, Rania R Tabet (Affiliation: Department of Ophthalmology and Visual Science, University of Texas Medical School Houston, Houston, TX 77030, USA. rmfeldman at swbell.net)
JournalJournal of glaucoma (J Glaucoma) 2008 Oct-Nov Vol. 17 Issue 7 Pg. 594-600 ISSN: 1536-481X United States
PMID18854740 (Publication Type: Journal Article, Review)
Topics
  • Blister (surgery)
  • Filtering Surgery (methods)
  • Glaucoma (surgery)
  • Humans
  • Intraocular Pressure
  • Needles
  • Postoperative Complications
  • Punctures
  • Reoperation