HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Optimal number of radioactive sentinel lymph nodes to remove for accurate axillary staging of breast cancer.

AbstractBACKGROUND:
Although sentinel lymph node (SLN) biopsy is the standard technique for staging the axilla of clinically node-negative breast cancer, the optimal number of radioactive SLNs to remove to ensure accuracy and minimize morbidity is still actively debated. The purpose of this study was to determine the minimum number of SLNs to excise to ensure accurate axillary staging of SLN-positive patients.
METHODS:
A total of 126 patients with invasive breast cancer underwent SLN biopsy by periareolar injection of radiolabeled technetium sulfur colloid on the day of surgery. The sequence in which SLNs were removed and the corresponding ex vivo radioactive counts were recorded. SLNs were removed until radioactive counts in the axilla were less than 10% of the ex vivo counts of the hottest SLN.
RESULTS:
A radioactive SLN was identified in every patient. The mean number of SLNs identified was 2.86 (range, 1-8). Clinicopathologic features associated with a positive SLN included a palpable tumor (P = .0035), increasing tumor size (P = .0039), increasing histologic grade (P = .0234), and angiolymphatic invasion (P < .001). The highest radioactive counts were found in the first node in 100 patients (79.4%), the second node in 15 (11.9%), and the third or later node in 11 patients (8.7%). Among the 38 patients with a positive SLN (30.2%), the hottest node was the first positive SLN in 27 patients (71.1%). The first positive SLN was the first node removed in 31 patients (81.6%) and after the second node in 37 patients (97.4%); it was removed in all patients by the third SLN.
CONCLUSION:
These data support the trend of limiting SLN biopsy to 3 lymph nodes. Removing all SLNs with radioactive counts greater than 10% of the ex vivo counts of the hottest SLN did not increase accuracy.
AuthorsMelanie A Lynch, Jeshaun Jackson, Julian A Kim, Rosemary A Leeming
JournalSurgery (Surgery) Vol. 144 Issue 4 Pg. 525-31; discussion 531-2 (Oct 2008) ISSN: 1532-7361 [Electronic] United States
PMID18847635 (Publication Type: Journal Article, Research Support, N.I.H., Extramural)
Chemical References
  • Technetium Tc 99m Sulfur Colloid
Topics
  • Adult
  • Aged
  • Analysis of Variance
  • Axilla
  • Biopsy, Fine-Needle
  • Breast Neoplasms (diagnostic imaging, pathology, surgery)
  • Cohort Studies
  • Female
  • Humans
  • Lymph Nodes (diagnostic imaging, pathology)
  • Middle Aged
  • Neoplasm Invasiveness (pathology)
  • Neoplasm Staging (methods)
  • Probability
  • Radionuclide Imaging
  • Retrospective Studies
  • Risk Assessment
  • Sensitivity and Specificity
  • Sentinel Lymph Node Biopsy (methods)
  • Technetium Tc 99m Sulfur Colloid

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: