Abstract | STUDY DESIGN: A retrospective clinical study with a follow-up of more than 7 years was conducted. OBJECTIVE: To compare interbody fusion, segmental lordosis and changes in disc and foramen height in patients who had received instrumented posterior lumbar interbody fusion (PLIF) with 1 or 2 closed-box titanium cages. SUMMARY OF BACKGROUND DATA: PLIF using 2 cages is a popular surgical method for treating degenerative lumbar spinal diseases. Implantation of a single cage in instrumented PLIF is still controversial. METHODS: From 1994 to 1997, 46 patients with degenerative lumbar spinal disease underwent single-level instrumented PLIF surgery using 1 (n = 22) or 2 (n = 24) interbody rectangular-shaped titanium blocks coated with Plasmapore (Prospace, B. Braun Aesculap AG, Tuttlingen). Mean follow-up was 8 years, ranging from 7 to 10 years. Anteroposterior and lateral radiographs of the patients were taken immediately after surgery and at the last follow-up examination. Segmental stability, change in segmental height, foramen height, and segmental lordosis were evaluated in both groups. RESULTS: Eight years after surgery, segmental stability (1-cage: 95.5%; 2 cages: 95.8%; P > 0.05), change in segmental height (1-cage: -1.9% +/- 3.7%; 2-cage: -2.4% +/- 3.6%; P > 0.05), foramen height (1-cage: -3.7% +/- 9.9%; 2-cage: -6.6% +/- 6.5%; P > 0.05) and segmental lordosis (1-cage: -2.4 degrees +/- 4.8; 2-cage -1.0 degrees +/- 4.0; P > 0.05) did not differ significantly between the 2 groups. Due to adjacent segment syndrome, 3 patients with a previous 2-cage PLIF received additional fusion surgery. CONCLUSION: In the long-term, instrumented PLIF with a single closed-box titanium cage shows similar radiologic results compared to fusion with 2 titanium cages. Implantation of a single titanium closed-box cage in an instrumented PLIF seems to be adequate in case of degenerative lumbar spinal disease.
|
Authors | Stefan Kroppenstedt, Martin Gulde, Robert Schönmayr |
Journal | Spine
(Spine (Phila Pa 1976))
Vol. 33
Issue 19
Pg. 2083-8
(Sep 01 2008)
ISSN: 1528-1159 [Electronic] United States |
PMID | 18758364
(Publication Type: Comparative Study, Journal Article)
|
Chemical References |
- Coated Materials, Biocompatible
- Titanium
|
Topics |
- Adult
- Aged
- Coated Materials, Biocompatible
- Equipment Design
- Female
- Humans
- Internal Fixators
- Lordosis
(diagnosis, physiopathology)
- Lumbar Vertebrae
(diagnostic imaging, physiopathology, surgery)
- Male
- Middle Aged
- Radiography
- Range of Motion, Articular
- Retrospective Studies
- Spinal Fusion
(instrumentation)
- Titanium
|