HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Maintenance of geometric alterations associated with percutaneous mitral valve repair: real-time three-dimensional echocardiographic assessment in an ovine model.

AbstractBACKGROUND AND AIM OF THE STUDY:
Percutaneous catheter-based mitral annuloplasty (PTMA) exploits the anatomic proximity of the coronary sinus (CS) to the mitral valve apparatus. Acute results of PTMA have been favorable, but the durability of the geometric alterations associated with PTMA has not been reported. The study aim was to assess the three-dimensional (3D) geometry of the mitral annulus (MA) in normal sheep at 20 weeks after PTMA implantation.
METHODS:
A PTMA device was implanted percutaneously in the CS of 10 normal sheep without mitral regurgitation. All animals were followed for 20 weeks with real-time 3D echocardiography (RT3DE). The MA area, the diagonal diameters in four directions, and the angle alpha, representing the degree of the saddle shape of MA, were determined.
RESULTS:
No significant hemodynamic, pathologic or mechanical complications were observed during implantation or follow up. Both, the MA area (from 4.8 +/- 0.9 cm2 to 3.7 +/- 0.9 cm2) and anterior-posterior (A-P) diameter (from 21.4 +/- 3.0 mm to 17.6 +/- 2.4 mm) were reduced immediately after the procedure (both p <0.05). The angle alpha decreased after the procedure (from 142.0 +/- 11.5 degrees to 128.3 +/- 15.6 degrees; p <0.05). These changes remained stable over the 20-week follow up period.
CONCLUSION:
RT3DE demonstrates that PTMA reduces the MA area and A-P diameter and maintains the physiologic curved or saddle shape of the MA. These changes remained stable for 20 weeks after device implantation.
AuthorsShota Fukuda, A Marc Gillinov, John R Liddicoat, Giuseppe Saracino, Motoya Hayase, William E Cohn, Christopher W Schneider, Takahiro Shiota
JournalThe Journal of heart valve disease (J Heart Valve Dis) Vol. 17 Issue 3 Pg. 276-82 (May 2008) ISSN: 0966-8519 [Print] England
PMID18592924 (Publication Type: Journal Article, Research Support, Non-U.S. Gov't)
Topics
  • Animals
  • Cardiac Catheterization
  • Cardiovascular Surgical Procedures (instrumentation, methods)
  • Computer Simulation
  • Echocardiography, Three-Dimensional
  • Heart Valve Prosthesis
  • Mitral Valve (diagnostic imaging, surgery)
  • Mitral Valve Insufficiency (surgery)
  • Models, Animal
  • Models, Cardiovascular
  • Sheep

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: