| Abstract | The authors developed a simple and rapid method for quantitation of 2-phenoxyethanol (2-PE) in DTwP vaccine based on reverse phase high performance liquid chromatography (HPLC). The method was simple and reproducible. The sensitivity of the assay was confirmed by spiking known amounts of 2-phenoxyethanol to the vaccine sample. |
| Authors | Bipin Sharma, Aditi Joseph, Anil Sood
(Affiliation: Panacea Biotec Ltd., Lalru, Patiala 140501, Punjab, India. bipinsharma1 at yahoo.com)
|
| Journal | Biologicals : journal of the International Association of Biological Standardization
(Biologicals)
Vol. 36
Issue 1
Pg. 61-3
(Jan 2008)
ISSN: 1045-1056 [Print] England |
| PMID | 17728142
(Publication Type: Journal Article)
|
| Chemical References |
- Diphtheria-Tetanus-Pertussis Vaccine
- Ethylene Glycols
- phenoxyethanol
|
| Topics |
- Calibration
- Chromatography, High Pressure Liquid
- Diphtheria-Tetanus-Pertussis Vaccine
(chemistry)
- Ethylene Glycols
(analysis, chemistry)
- Reproducibility of Results
- Time Factors
|