Abstract | PURPOSE: To retrospectively review the surgical technique, postoperative therapy/splinting protocols, and clinical and radiographic outcomes of patients who had pyrolytic carbon proximal interphalangeal (PIP) joint arthroplasty. METHODS: A total of 50 PIP joint replacements in 35 patients were performed with a minimum follow-up period of 27 months. Indications for surgery included pain, decreased range of motion, instability, and/or deformity. The preoperative diagnosis was osteoarthritis in 14, rheumatoid arthritis in 11, and posttraumatic arthritis in 10. There were 20 women and 15 men affected. The average age at the time of surgery was 53 years. The fingers replaced included the index (15), middle (18), ring (10), and small (7). The preoperative arc of motion averaged 40 degrees (0 degrees-60 degrees ), and the pinch and grip measurements averaged 3 and 19 kg, respectively. The preoperative pain scores averaged 6 (scale, of 0-10) on a visual analog space scale. RESULTS: The arc of motion was 47 degrees after surgery, and the average pinch and grip measurements were 4 and 25 kg, respectively. Pain scores improved to 1. At the final follow-up evaluation the overall patient satisfaction was nearly 80%. The results of index finger PIP replacements are compatible with other digits. Fourteen joints (in 14 patients) to date have required additional procedures to improve or maintain joint motion/function or pain; 5 for minor reasons and 9 for major complications. The revision arthroplasty rate was 8%. No infections were noted. Although not medically necessary, 2 patients requested and had an amputation. Radiographic subsidence and subsequent settling (in accordance with Wolff's law) without apparent loosening occurred in 20 joints. CONCLUSIONS: Our 2-year minimum follow-up evaluation of pyrolytic carbon implant arthroplasty showed improved pain relief and good overall patient satisfaction. Twenty-eight percent of patients required a second procedure and 8% required a revision arthroplasty. Radiographs showed gross changes in implant and eventual settling to a stable position in 40% of the joints. A longer follow-up period will help to better determine the efficacy of this implant. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic, Level IV.
|
Authors | César J Bravo, Marco Rizzo, Kirsten B Hormel, Robert D Beckenbaugh |
Journal | The Journal of hand surgery
(J Hand Surg Am)
Vol. 32
Issue 1
Pg. 1-11
(Jan 2007)
ISSN: 0363-5023 [Print] United States |
PMID | 17218170
(Publication Type: Journal Article, Research Support, Non-U.S. Gov't)
|
Chemical References |
- Biocompatible Materials
- pyrolytic carbon
- Carbon
|
Topics |
- Adult
- Aged
- Analysis of Variance
- Arthritis
(surgery)
- Arthroplasty, Replacement
(methods)
- Biocompatible Materials
- Carbon
- Female
- Finger Joint
(diagnostic imaging, surgery)
- Follow-Up Studies
- Humans
- Joint Prosthesis
- Male
- Middle Aged
- Pain Measurement
- Postoperative Complications
- Prosthesis Design
- Radiography
- Range of Motion, Articular
- Reoperation
- Retrospective Studies
- Splints
- Treatment Outcome
|