Should 3K zoom function be used for detection of pneumothorax in cesium iodide/amorphous silicon flat-panel detector radiographs presented on 1K-matrix soft copies?

Abstract
The purpose of the study was to evaluate observer performance in the detection of pneumothorax with cesium iodide and amorphous silicon flat-panel detector radiography (CsI/a-Si FDR) presented as 1K and 3K soft-copy images. Forty patients with and 40 patients without pneumothorax diagnosed on previous and subsequent digital storage phosphor radiography (SPR, gold standard) had follow-up chest radiographs with CsI/a-Si FDR. Four observers confirmed or excluded the diagnosis of pneumothorax according to a five-point scale first on the 1K soft-copy image and then with help of 3K zoom function (1K monitor). Receiver operating characteristic (ROC) analysis was performed for each modality (1K and 3K). The area under the curve (AUC) values for each observer were 0.7815, 0.7779, 0.7946 and 0.7066 with 1K-matrix soft copies and 0.8123, 0.7997, 0.8078 and 0.7522 with 3K zoom. Overall detection of pneumothorax was better with 3K zoom. Differences between the two display methods were not statistically significant in 3 of 4 observers (p-values between 0.13 and 0.44; observer 4: p = 0.02). The detection of pneumothorax with 3K zoom is better than with 1K soft copy but not at a statistically significant level. Differences between both display methods may be subtle. Still, our results indicate that 3K zoom should be employed in clinical practice.
AuthorsKarin A Herrmann, H M Bonél, A Stäbler, M Voelk, M Strotzer, C J Zech, M F Reiser
JournalEuropean radiology (Eur Radiol) Vol. 16 Issue 12 Pg. 2768-74 (Dec 2006) ISSN: 0938-7994 [Print] Germany
PMID16896703 (Publication Type: Journal Article)
Chemical References
  • Contrast Media
  • Iodides
  • Cesium
  • Iohexol
  • iopromide
  • cesium iodide
  • Silicon
Topics
  • Adult
  • Aged
  • Area Under Curve
  • Cesium
  • Contrast Media
  • Female
  • Humans
  • Iodides
  • Iohexol (analogs & derivatives)
  • Male
  • Middle Aged
  • Observer Variation
  • Pneumothorax (diagnostic imaging)
  • Radiography, Thoracic (instrumentation)
  • Silicon
  • X-Ray Intensifying Screens

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: