Failure of anti-retraction valves and the procedure for between patient flushing: a rationale for chemical control of dental unit waterline contamination.

AbstractPURPOSE:
To evaluate the efficacy of anti-retraction valves; and to compare between-patient flushing with water and with using a chemical treatment to control patient-to-patient contamination through dental unit waterlines (DUWL).
METHODS:
For the first aim, nine new antiretraction valves from three different manufacturers were utilized. Each valve was installed along the water line connecting the high-speed handpiece to the dental unit. The handpieces were made to run and stop in a container filled with a solution of about 7 log10/mL of Bacillus subtilis spores (used as a marker) and retraction of spores was measured. Subsequently, all nine valves were installed in dental units in use in private offices, and all tests repeated after 15, 30 and 60 working days. For the second aim, the efficacy of mechanical flushing (30 seconds for each instrument) was compared with that of mechanical flushing in combination with pressurized air and of a between-patient disinfecting procedure (2 minutes contact with TAED and persalt utilizing an "autosteril" system). Before each test (10 tests for each procedure), known concentrations of Pseudomonas aeruginosa (ATCC 27853) suspension (4 to 7 log10cfu/mL) was loaded in the DUWL and let sit for 20 minutes.
RESULTS:
In the anti-retraction valve experiment, at baseline only one anti-retraction valve showed a failure in opposing fluid retraction. After 15 days, three valves, after 30 days, six valves, and after 60 days, eight valves showed failure. In the flushing experiment, a highly significant linear correlation (r =.9178) was found between values before and after mechanical flushing. Post flush log10cfu/mL values showed the removal of about only 1 log10cfu/mL of the microorganisms (only about 10% in absolute counts). On the other hand, no cfu/mL was detected in waterlines after the "autosteril" disinfecting cycles.
AuthorsLucio Montebugnoli, Giovanni Dolci, David Alexander Spratt, Raghunath Puttaiah
JournalAmerican journal of dentistry (Am J Dent) Vol. 18 Issue 4 Pg. 270-4 (Aug 2005) ISSN: 0894-8275 [Print] United States
PMID16296436 (Publication Type: Journal Article)
Chemical References
  • Dental Disinfectants
  • Detergents
  • Ethylenediamines
Topics
  • Colony Count, Microbial
  • Decontamination (methods)
  • Dental Disinfectants
  • Dental Equipment
  • Detergents
  • Equipment Contamination
  • Equipment Failure
  • Ethylenediamines
  • Infection Control, Dental (instrumentation, methods)
  • Linear Models
  • Pseudomonas aeruginosa
  • Spores, Bacterial
  • Water Microbiology

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: