Abstract | OBJECTIVES: To compare effects of waterproof covering on finger skin temperature (FST) and subjective hand pain during immersion tests using cold water at 10 degrees C, 12 degrees C and 15 degrees C. In the (Draft International Standard) of the International Organization for Standardization (ISO/DIS 14835-1), a water temperature of 12 degrees C and use of water covering are proposed. METHODS: Six healthy male subjects took part in the immersion tests and immersed both hands into water at 10 degrees C, 12 degrees C and 15 degrees C for 5 min, repeatedly, with waterproof covering ( polyethylene gloves) or without (bare hands). The FST data from middle fingers and subjective pain scores for hand pain were analyzed. Furthermore, the test with water at 12 degrees C was repeated to assess the repeatability of the test. RESULTS: The glove and water temperature factors for FST were significant at every minute from 1 min during immersion up to 2 min after recovery, showing higher values for waterproof covering than for bare hands and showing lowest values for water temperature of 10 degrees C and highest for 15 degrees C. The glove and water temperature factors for subjective pain score were significant at the 1-min and 2-min points during immersion, showing lower scores for waterproof covering than for bare hands and showing highest scores for water temperature of 10 degrees C and lowest for 15 degrees C. The results of the first and second tests using water of 12 degrees C showed no systematic difference in FST and hand pain between the tests, with a few exceptions. CONCLUSIONS: Subjective pain during the cold immersion test with polyethylene gloves and water at 12 degrees C can be reduced, while the differences in FST between water temperatures of 10 degrees C and 12 degrees C were small or not apparent at some points during immersion and recovery. The test also seems to be suitable for repeatability. Further investigation on hand-arm vibration syndrome (HAVS) patients to validate the use of the immersion test with gloves to obtain sufficient data for diagnostic value is required.
|
Authors | K Suizu, N Harada |
Journal | International archives of occupational and environmental health
(Int Arch Occup Environ Health)
Vol. 78
Issue 4
Pg. 311-8
(May 2005)
ISSN: 0340-0131 [Print] Germany |
PMID | 15815917
(Publication Type: Journal Article)
|
Topics |
- Adult
- Cold Temperature
- Gloves, Protective
- Hand
- Humans
- Immersion
- Japan
- Male
- Pain Measurement
- Protective Clothing
- Skin Temperature
- Vibration
(adverse effects)
|