Abstract |
In the 1995-2000 period, data of interest concerning preoperative and postoperative intraocular pressure (IOP) and the best corrected visual acuity (BCVA) in the group of eyes in which the brand name methylcellulose--Adatocel, Ocucoat, Metocel--(n=378) and Viscoat (n=526) was used during the surgery, were statistically evaluated. They were compared to those results obtained from the prospective clinical study performed in 2001-2002 (n=275) by using the new viscoelastic material Duo-Bonharen, which is the Czech product, manufactured on the basis of the hyaluronic acid. All groups were evaluated in a retrospective manner. In the comparative study, statistically significant differences in functional results of cataract surgery in favor of Duo-Bonharen were demonstrated. The cohesive type of the substance used tends to decrease the IOP, the dispersive materials tend to increase the IOP.
|
Authors | Abdulhafiz Al-Farzai, J Novák, F Hubálek |
Journal | Ceska a slovenska oftalmologie : casopis Ceske oftalmologicke spolecnosti a Slovenske oftalmologicke spolecnosti
(Cesk Slov Oftalmol)
Vol. 60
Issue 3
Pg. 205-11
(May 2004)
ISSN: 1211-9059 [Print] Czech Republic |
Vernacular Title | Duo-Bonharen v komparativní studii. |
PMID | 15307655
(Publication Type: Clinical Trial, Comparative Study, English Abstract, Journal Article)
|
Chemical References |
- Duo-Bonharen
- Hyaluronic Acid
- Methylcellulose
|
Topics |
- Aged
- Cataract Extraction
- Female
- Humans
- Hyaluronic Acid
(administration & dosage)
- Intraocular Pressure
(drug effects)
- Male
- Methylcellulose
(administration & dosage)
|