HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

Change in distant atrial activation patterns during circumferential pacemapping of pulmonic vein ostium: implications for localizing triggers for atrial fibrillation.

AbstractINTRODUCTION:
Unique intracardiac activation patterns recorded from multipolar catheters in the coronary sinus (CS) and posteromedial right atrium (RA) when pacing from ostium (os) of each pulmonic vein (PV) can serve as template for determining PV of origin of atrial premature complexes. Development of an accurate template requires knowledge of variations in activation pattern during pacing from different aspects of same PV.
METHODS:
In 25 patients undergoing catheter ablation for AF, a decapolar Lasso mapping catheter was placed at PV os of interest and multipolar catheters were placed in CS and RA-medial to crista terminalis (CT). For each PV, pacing was performed from Lasso catheter poles 1 through 10. For each bipole paced, activation sequence in CS (proximal to distal & vice-versa) was assessed, activation time (pacing stimulus to earliest electrogram recorded in catheters in CS/along CT) was measured and difference (CS - CT time) was determined. Significant interpolar variation was defined as the difference between the shortest and longest CS - CT activation time of >/=25 msec when pacing from different bipoles of same PV.
RESULTS:
In 59 PVs [19 right superior (RS), 20 left superior (LS), 8 right inferior (RI) and 12 left inferior (LI)], 259 bipoles were paced (median of 4 bipoles/PV). During circumferential PV pacing activation sequence in CS catheter was distal to proximal in 84.4% left-sided PVs (LSPV and LIPV) and proximal to distal in 92.6% right-sided PVs (RSPV and RIPV) with no change in activation sequence observed during pacing from different bipoles in same PV. Significant interpolar variation was observed with circumferential pacing in 1 of 19 RSPV (5.3%), 2 of 20 LSPV (10%), 1 of 12 LIPV (8.3%) and none of RIPV.
CONCLUSION:
Unique intracardiac activation patterns during ostial pacing from individual PV are not influenced by circumferential location of pacing site.
AuthorsSanjay Dixit, Edward P Gerstenfeld, Robert W Rho, Vickas Patel, David J Callans, Francis E Marchlinski
JournalJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing (J Interv Card Electrophysiol) Vol. 8 Issue 3 Pg. 187-94 (Jun 2003) ISSN: 1383-875X [Print] Netherlands
PMID12815304 (Publication Type: Journal Article)
Topics
  • Atrial Fibrillation (diagnosis, physiopathology)
  • Cardiac Catheterization
  • Cardiac Pacing, Artificial
  • Catheter Ablation
  • Coronary Vessels (physiopathology)
  • Electrophysiologic Techniques, Cardiac (methods)
  • Heart Conduction System
  • Humans
  • Middle Aged
  • Pulmonary Veins (physiopathology)

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: