HOMEPRODUCTSCOMPANYCONTACTFAQResearchDictionaryPharmaSign Up FREE or Login

A prospective, randomized, multicentered controlled trial to compare the annual outcomes of patients with diabetes mellitus monitored with weekly fructosamine testing versus usual care: a 3-month interim analysis.

Abstract
The recent introduction of a home monitoring system that measures whole blood glucose and whole blood fructosamine values by fingerstick blood drop adds a previously unavailable estimate of overall glycemic control via the fructosamine component. Fructosamine serves as an indicator of overall glycemic control for a 10-14-day time frame versus the 90-day average indicated by the hemoglobin A1c (A1C) test. The utilization of the fructosamine test for management of patients with diabetes mellitus remains unclear. The primary objectives of this study are to compare the quarterly A1C results of subjects monitoring weekly fructosamine with those receiving usual care, to identify the number of patients achieving goal A1C, and to determine if the addition of a weekly fructosamine test changes a patient's quality of life. Secondary objectives include determining if specific patient demographics predict success or difficulty in achieving improved A1C. This is a prospective, randomized, multicenter controlled trial. Patients were randomly assigned to collect weekly fructosamine in addition to daily glucose (Group 1) or usual care of daily glucose (Group 2) and had study visits every 3 months. Baseline and quarterly A1C tests were collected. Quality of life assessment was conducted at baseline and will be evaluated at the final study visit. Sixty subjects have been randomized into the study since May 2001 with enrollment ongoing. Baseline demographics, glucose, fructosamine, and A1C were similar between the two groups. The 3-month interim analysis demonstrated no statistically significant difference in fructosamine (p = 0.265) between Group 1 (293.00 +/- 111.22 micromol/L) and Group 2 (336.69 +/- 111.12 micromol/L), respectively. No statistical difference at 3 months (p = 0.676) in A1C values for Group 1 (7.921 +/- 1.848% vs. 7.755 +/- 1.408%) and Group 2 (7.800 +/- 1.505% vs. 7.971 +/- 1.797%) were noted when compared with baseline. The interim data suggest that the fructosamine group has had a net decrease in A1C over the 3-month time frame, whereas the control group has had a net increase in A1C values. Ongoing follow-up will determine if this trend continues and becomes statistically and clinically significant.
AuthorsCameron C Lindsey, Alan W Carter, Stacy Mangum, Dorothy Greene, Antoine Richardson, Sherrill Brown, Bridget McCandless
JournalDiabetes technology & therapeutics (Diabetes Technol Ther) Vol. 4 Issue 5 Pg. 637-42 ( 2002) ISSN: 1520-9156 [Print] United States
PMID12450445 (Publication Type: Clinical Trial, Journal Article, Multicenter Study, Randomized Controlled Trial)
Chemical References
  • Glycated Hemoglobin A
  • Hypoglycemic Agents
  • Fructosamine
Topics
  • Aging (physiology)
  • Blood Glucose Self-Monitoring
  • Body Mass Index
  • Body Weight (physiology)
  • Diabetes Mellitus (blood, psychology, therapy)
  • Double-Blind Method
  • Exercise
  • Female
  • Fructosamine (blood)
  • Glycated Hemoglobin (analysis)
  • Humans
  • Hypoglycemic Agents (therapeutic use)
  • Male
  • Middle Aged
  • Prospective Studies
  • Quality of Life
  • Racial Groups
  • Sex Characteristics
  • Treatment Outcome

Join CureHunter, for free Research Interface BASIC access!

Take advantage of free CureHunter research engine access to explore the best drug and treatment options for any disease. Find out why thousands of doctors, pharma researchers and patient activists around the world use CureHunter every day.
Realize the full power of the drug-disease research graph!


Choose Username:
Email:
Password:
Verify Password:
Enter Code Shown: